The updated guidance specific to this version
Warning
• For this version, you must do a two-phase update, update the operating system first and then
software updates rest if your copier is in an older version v3801.
• Some copiers on the screen is wrong. Do not follow any onscreen
guides without considering the corresponding item in the document.
• You need to use a USB memory key is recognized by the copier. A list of test
device found in the bulletin Digital-94 and Digital-95. If you use a USB memory key
More than one of these devices, the best practice is to confirm the update operation on a
Photocopier at the store before performing an update in this regard.
• Print out a photo, and backup logs, forms, address books,
parts numbers and other data stored on the hard drive before doing the update. in some
case, you need to format the drive after the update. Logs are backed up using
procedures in the hands of the Administrator Chapter 4 Managing network equipment,
Maintain access from TOP ~ Backup data. The code is the best support
using FSMS.
Update OS procedure: You first this
1. Install Data ROM.bin in the root directory of an empty USB memory device
formatted as FAT (FAT23 does not). This file is found in the rom-bin directory of
download package.
2. Turn off the copier.
3. Remove any existing USB dongle from the USB port (s) and insert the USB memory
equipment containing files ROM.bin.
4. Power up copier hold [4] and [9] keys
5. Press 0 to select the operating system to update and uncheck 1 ~ 6. The operating system update. there will
not a description for the firmware package 1 and 3: This is normal.
6. Click [START] and let the update run to completion.
7. When the operation is finished, turn off the power and unplug the USB memory device.
Continue to the procedure on the next page
Update Procedures rest Firmware
1. Copy the update file to the USB memory device. The files go in the root directory.
The files can also go into a folder with name specific models appropriate if the copier
has an appropriate level or a later version. The directory pattern is:
model directory
e-STUDIO3511 / 4511: 35_4511 300 16/02/05
e-STUDIO350 / 450: 350_450 300 16/02/05
e-STUDIO200L / 230/280: 230_280 300 09/03/05
eg If you're updating equipment and e-STUDIO450 your USB is mapped to
drive F on your computer, you can put the files in F: \. If you are already a photocopier in
System version 300, you can put the files in F: \ or F: \ 350_450.
Do not put any files in directories other than the update files updates. USB
device must be formatted as FAT (FAT32).
2. If the copier model can print or scan enablers installed, uninstall them first. with
power off, insert the USB memory device into the USB port on the right side of
Photocopiers. Some models have 2 ports: either can be used. Electricity to hold copiers
4 and 9 keys.
3. Wait about 5 minutes for the following screen will be displayed (screens
changed slightly by model):
Download the Firmware Update Mode store
Choose Update restaurant
0. OS Update Version UIF xxxx
* 1. HDD UI0 Update Version xxxx
* 2. Update UI UI1 Version xxxx
* 3. System Firmware Update Version SYS xxxx
* 4. NIC NIC Firmware Update Version xxxx
* 5. Scanner Firmware Update Version SCN xxxx
* 6. Air Firmware Update Version xxxx MCN
Minimum SYS
Version
* This means that the software is selected for updates. Note that by default, the operating system is de-selected
and all other software is selected. This is not the exact combination possibilities. specific
select the firmware that needs to be updated. In most cases, you will select all items. If you
update the computer and scans using EPROM jig, then you will deselect the
goods.
4. Click Start to begin the update process. As each individual from being updated,
photocopier screen will list that as complete ROM. This process is not complete until all
ROM has been updated and the screen says "Update completed".
Download the Firmware Update Mode store
HD Data Update ... Finished
Download Storage -> FROM Update Start. UI Data Update ... Finished
SysFirm Update ... Finished
Test Equipment - Complete
Status Updates - Complete
Test data - Completed
Update Complete (Note 1)
Be Serial Storage Key. Push Button 'START' !! (Note 2)
Note 1: The update is not done until this message is displayed
Note 2: The announcement says that the key to the next storage connection is not correct.
5. When the update has run to completion, each firmware package should be listed in
Screen photocopiers complete. The screen will display at the bottom: "Xin
Connect to warehouse KEY. Push 'Start' Button. "
This message is incorrect.
When "Please connect to the next important storage ..." message is displayed, updated
complete. Electrical down copier and remove the USB memory device.
6. Power on the copier mode 08 Code 947. 08. Making Turn off copiers.
7. Power on the copier. If you get the message "Wait, warm UP" and copiers do
not to get ready after waiting a long time, as codes 08-690. Confirm normal
activity. Print out a list of codes 900 through 950 print and compare with the goals
historical value to validate firmware ROM is in the appropriate version ..
(This is a common screen. It is different for different family models.)
HDD repeat procedures in e-Bridge Machinery
overview
This procedure should be used in the following cases:
Machine locked up and no 08/690
Before indicating that the hard drive is replaced
Update firmware on the HDD or UI component data
STEPS
1. Support mode PWR / Clear / 3 pick # 3 PWR down completion
2. Support mode PWR / Clear / 3 pick # 2 PWR down completion
3 PWR / 690 = 2 PWR 0/8 down when rebooting is displayed - replace the HDD if a restart is not
display after 5 minutes or an error message occurs
4. Recover the firmware through the jig recovery
PWR / 8/9 with jig reset
You just choose 0 AN1 (OS and HDD) for most of the recovery. be sure
NIC is de-selected (Downgrading a NIC card can cause permanent damage).
Machine shuts off when the "Update Completed" is displayed
If you are troubled about the updates of the main USB or Scan to work,
Data download and use EPROM EPROM jig to perform the update.
5 Turn ordinary machine and check the basic copy function, if the basic functions seem
implementation to step 6, if they do not fix the issue. (See bottom of page)
6. Update the firmware via USB
Follow the instructions that are described earlier in this document.
7. Check all the functions of the machine, if the machine fails, try "Additional steps".
PERFECT
Additional steps -
(Only be done if you are still having issues)
Some additional steps may be required if there are problems:
If a specific target failed
If no specific targets (eg, target 13) using DLM table and try to update the table failed
direct. Usually, it is either the SLG or machine table
1. PWR / Clear / 3 select # 1 PWR down completion
2. PWR / PWR 669 stocks down 0/8 complete
3. Follow the procedure on page 5-141 of Service Manual Ver 2 next
two above
Touch Panel
If the touch panel is not calibrated in any of the above steps, perform
PWR / 0/8 / code 692
Download E-Studio 3511C Firmware
0 comments:
Post a Comment